Análisis del flujo libre generado por un ventilador axial de dos palas


Analysis of the Free Flow Generated by a Two-Blade Axial Fan


Tiburcio Fernández Roque
Instituto Politécnico Nacional, Ciudad de México, MÉXICO

José Arturo Correa Arredondo
Instituto Politécnico Nacional, Ciudad de México, MÉXICO

Jorge Sandoval Lezama
Instituto Politécnico Nacional, Ciudad de México, MÉXICO

Alejandro Mejía Carmona
Instituto Politécnico Nacional, Ciudad de México, MÉXICO

Víctor Manuel Sauce Rangel
Instituto Politécnico Nacional, Ciudad de México, MÉXICO

Antonio Mosqueda Sánchez
Instituto Politécnico Nacional, Ciudad de México, MÉXICO

Lizeth Hernández
Instituto Politécnico Nacional, Ciudad de México, MÉXICO

Recibido 09-06-2023, aceptado 02-02-2024.

Resumen

En este trabajo se analiza experimentalmente el flujo generado por un ventilador axial de dos palas con el fin de determinar la posición en la cual se encuentra la velocidad axial inducida máxima promedio y el radio de la contracción del flujo en dicha posición. Para esto se determinó la distribución radial de la velocidad axial inducida en diversos planos paralelos al plano de rotación del ventilador. De los datos obtenidos se determinó que la velocidad axial inducida máxima promedio se encuentra a una distancia igual al 33 % del radio del ventilador y que el radio de la contracción en dicha posición es del 70.2 % del radio del ventilador. De igual manera, se encontró que la velocidad axial inducida local es máxima en el límite radial de la contracción del flujo generado por el ventilador y es mayor mientras más cerca está del plano de rotación.


Abstract

This paper analyses experimentally the flow generated by a two blades axial fan to determine the position in which the average induced axial velocity is maximum and the radius of the flow contraction (wake) in that position. For this, the radial distribution of the induced axial velocity in different planes parallel to the plane of fan rotation was measured. From the data obtained it was determined that the average maximum induced axial velocity is at a distance equal to 33% of the radius of the fan and the contraction radius at that position is 70.2% of the fan radius. Similarly, it was found that the local induced axial velocity is maximum in the radial limit of the flow contraction generated by the fan and is higher while the plane of rotation is closer.

Palabras clave: ventilador axial, velocidad inducida, contracción del flujo.
Index terms: axial fan, induced flow, flow contraction.


ISO 690 reference:
Fernández Roque, Tiburcio; Correa Arredondo, José Arturo; Sandoval Lezama, Jorge; Mejía Carmona, Alejandro; Sauce Rangel, Víctor Manuel; Mosqueda Sánchez, Antonio, 2024, Análisis del flujo libre generado por un ventilador axial de dos palas, Científica, vol. 28, no. 1, ISSN 2594-2921, DOI: https://doi.org/10.46842/ipn.cien.v28n1a03